Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])

Accuracy Specifications
Function Range Resolution Accuracy
AC Volts
(40 Hz to 500Hz)1
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0 % + 3
DC Volts 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 3
AC Millivolts 600.0 mV 0.1 mV 3.0 % + 3
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitance2 50.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency3 Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
NA
Duty Cycle3 1 % to 99 % 0.1 % NA
AC Current
(40 Hz to 200 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC Current 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
  1. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
  2. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
  3. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
AC Volts 600 V 1 >10 MΩ <100 pF 2 >60 dB at dc,
50 Hz or 60 Hz
\AC Millivolts 600 mV >1M, <100 pF >80 dB at 50 Hz or 60 Hz
DC Volts 600 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
  1. 6 x 105 V Hz Max
  2. For mV (AC), input impedance is approximately 1 MΩ.
General Specifications
Maximum Voltage Between any Terminal and Earth Ground 600 V
Display (LCD) 6000 counts, updates 3/sec
Battery Type 2 AAA, NEDA 24A, IEC LR03
Battery Life 200 hours minimum
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative Humidity
Operating Humidity Non-condensing when <10°C
≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
Operating Humidity, 40 MΩ Range ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature Coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse Protection for Current Inputs 11A, 1000V Fast Fuse, Fluke specified part only
Size (HxWxL) 142 mm x 69 mm x 28mm
Weight 200 g
IP Rating IEC 60529: IP 40
Safety IEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic Environment IEC 61326-1: Portable
Electromagnetic Compatibility Applies to use the Korea only.  Class A Equipment (Industrial Broadcasting and Communication Equipment)1
رمز المنتج: FLUKE-106 التصنيفات: , ,

ماركة

FLUKE

شركة FLUKE Corporation هي الشركة الرائدة عالميًا في تصنيع وتوزيع وصيانة أدوات الاختبار الإلكترونية والبرمجيات ، منذ تأسيسها في عام 1948 ، ساعدت شركة FLUKE في تحديد وتنمية سوق تكنولوجيا فريدة من نوعها ، من خلال توفير قدرات الاختبار واستكشاف الأخطاء وإصلاحها التي نمت إلى مستوى بالغ الأهمية في صناعات التصنيع والخدمات ، يمثل كل مصنع تصنيع أو مكتب أو مستشفى أو منشأة جديدة يتم بناؤها اليوم عميلًا محتملًا آخر لمنتجات FLUKE.

بالاعتماد علي 0 مراجعه

٪ s بشكل عام
0
0
0
0
0

Be the first to review “جهاز أفوميتر ديجيتال بحجم الجيب 600 فولت FLUKE موديل 106”

لا توجد توصيات بعد.

قد يعجبك أيضاً…

عربة التسوق

close