كلامب أمبير ديجيتال FLUKE موديل 319


Fluke 319 AC/DC True RMS Clamp Meters /1000A AC/DC current measurement

13350 جنيه

قارن

Specifications: Fluke 317/319 Clamp Meters

General specifications
Digital display 6000 count resolution
Low battery Indication Displays a signal when the batteries are below their required voltage
Power source Three AAA IEC LR03 batteries
Clamp opening size 1.45 in (37 mm)
Jaw diameter 1.45 in (37 mm)
Dimensions (L x W x H) 9.21 in x 2.95 in x 1.37 in
(234.0 mm x 75.0 mm x 34.8 mm)
Weight Approximately 13.5 oz (384 g) (batteries included)
Auto range Available in Ohms
Safety CE
EN/IEC 61010-1 and IEC 61010-2-032
Measurement Category: 600V CAT III
317 Electrical specifications
Current AC Range 40.00 A, 600.0 A
Resolution 0.01 A, 0.1 A
Accuracy 1.6% ±6 digit (50-60 Hz) {40 A}
2.5% ±8 digit (60-500 Hz) {40 A}
1.5% ±5 digit (50-60 Hz) {600 A}
2.5% ±5 digit (60-500 Hz) {600 A}
Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A
AC response rms
Current DC Range 40.00 A, 600.0 A
Resolution 0.01 A, 0.1 A
Accuracy 1.6% ±6 digit (40 A)
1.5% ±5 digit (600 A)
Voltage AC Range 600.0 V
Resolution 0.1 V
Accuracy 1.5% ±5 digit (20-500Hz)
AC response rms
Voltage DC Range 600.0 V
Resolution 0.1 V
Accuracy 1% ±4 digit
Resistance Range 400.0 Ω, 4000 Ω
Resolution 0.1 Ω, 1 Ω
Accuracy 1% ±5 digit
Continuity ≤ 30 Ω
Inrush Integration time N/A
Frequency Range N/A
Accuracy N/A
Trigger Level N/A
319 Electrical specifications
Current AC Range 40.00 A, 600.0 A, 1000 A
Resolution 0.01 A, 0.1 A, 1 A
Accuracy 1.6% ±6 digit (50-60 Hz) {40 A}
2.5% ±8 digit (60-500 Hz) {40 A}
1.5% ±5 digit (50-60 Hz) {600/1000 A}
2.5% ±5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC response rms
Current DC Range 40.00 A, 600.0 A, 1000 A
Resolution 0.01 A, 0.1 A, 1 A
Accuracy 1.6% ±6 digit (40 A)
1.5% ±5 digit (600/1000 A)
Voltage AC Range 600.0 V
Resolution 0.1 V
Accuracy 1.5% ±5 digit (20-500Hz)
AC response rms
Voltage DC Range 600.0 V
Resolution 0.1 V
Accuracy 1% ±4 digit
Resistance Range 400.0 Ω
4000 Ω
Resolution 0.1 Ω
1 Ω
Accuracy 1% ±5 digit
Continuity ≤ 30 Ω
Inrush Integration time 100 ms
Frequency Range 5.0 – 500.0 Hz
Accuracy 0.5% ±5 digit
Trigger Level 10 – 100 Hz ≥ 5 A, 5 – 10 Hz, 100 – 500 Hz ≥ 10 A
The accuracy specifications aply at 73 °F ±41 °F (23 °C ±5 °C)
Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C.
True rms for ac V and ac A accuracy is specified from 5% to 100% of range.
Environmental specifications
Operating temperature 14°F to 122°F (-10 °C to 50 °C)
Storage temperature -40 °F to 140 °F (-40 °C to 60 °C)
Operating humidity Non-condensing (< 50 °F) (< 10 °C)
90% RH (50 °F to 86 °F) (10 °C to 30 °C)
75% RH (86 °F to 104 °F) (30 °C to 40 °C)
45% RH (104 °F to 122 °F) (40 °C to 50 °C)
(Without condensation)
Operating altitude 1 mile (2000 meters) above mean sea level
Storage altitude 7 miles (12,000 meters) above mean sea level
IP Rating IP40
Vibration requirements Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
Drop test requirements 3 ft (1 m) drop test, six sides, oak floor
EMI, RFI, EMC Instrument unspecified for use in EMC field ≥ 0.1 V/m
Temperature coefficients 0.1x (specified accuracy)/ °C
(<64 °F or > 82° F)
(<18 °C or > 28 °C)

ماركة

FLUKE

شركة FLUKE Corporation هي الشركة الرائدة عالميًا في تصنيع وتوزيع وصيانة أدوات الاختبار الإلكترونية والبرمجيات ، منذ تأسيسها في عام 1948 ، ساعدت شركة FLUKE في تحديد وتنمية سوق تكنولوجيا فريدة من نوعها ، من خلال توفير قدرات الاختبار واستكشاف الأخطاء وإصلاحها التي نمت إلى مستوى بالغ الأهمية في صناعات التصنيع والخدمات ، يمثل كل مصنع تصنيع أو مكتب أو مستشفى أو منشأة جديدة يتم بناؤها اليوم عميلًا محتملًا آخر لمنتجات FLUKE.

بالاعتماد علي 0 مراجعه